7 IN 7 OUT Rapid Shutdown Firefighter Safety Switch
Main loop parameters
Number of strings
7strings
Max DC voltage
1500V DC
Max DC current
40A
Parameters
1500V26A,1000V40A,600V40A
DC connector
MC4
Control loop parameters
Power supply type
AC single phase
Nominal voltage
230V AC
Operating voltage
100-270V AC
Nominal frequency
50 Hz
Operating frequency
47-53H2
Nominal current
30mA
Max current
300mA
AC connector
Plug-in
Product parameters
Protection degree
IP 65
Protection level
Class lI
Certification
CE
Switch according to
EN60947-3
Number of operations
>10000
N.of operations under load
>1500
Operating temperature
-20℃~ 70℃
Temperature sensor trigger
70℃
Warranty
5 years
Dimensions(L*W*H)
348 * 330 * 173
Weight
5800g
Product Description
The Sun Provides Energy,Slocable Provides Safety
In most photovoltaic systems,theDC isolator is integrated into the DC/AC powerinverter.After switching off the DC isolator,the ables between the solar modulesand the inverter running through the building are still subject to up to 1000VDC.
In the event of a fire, firefighters are exposed to a serious source of potentialdanger.The Slocable Rapid Shutdown Firefighter Safety Switch provides the solution. Rapid Shutdown Device directlydisconnects the DC current in close proximity to the solar modules and createsa safer situation for firefighters.
Advantages of our Rapid Shutdown Firefighter Safety Switch:
1~10 strings available
Upto40A
Upto1500V DC
CE certification
APP remote control
Motor driven switch disconnection
High grade PC, IP65 protection &unti UV
Knock outs丨Cable glands丨MC4 connectors
Built-in DC isolator with CE,1P65
Shut down automatically exceeding 80°C
Rapid Shutdown is equipped with breathing valve to avoid conden-sation inside the enclosure.
Rapid Shutdown is designed for residential solar installations.
1. AC Power manually shut down Any firefighter in fighting a fire is to shut down the main AC power circuit at first.This makes itpossible to start extinguishing the actual fire without the risk of electrocution.Slocable developed the Rapid Shutdown Devices according to this standard international safety routine. Rapid Shutdown Device prevents firefightersfrom having to take any extra action in case of afire,maximizing the safety in the event of a fire.
2. Automatic DC Power Shut Down When a firefighter shuts down the main ACcircuit,the SRS will detect this.If this power down situationlasts,it will automatically switch to the OFF position in 5 seconds.Since the SRS is located close to the PVmodules,the high voltage DC current from the PV modules will be completely isolated,which leaves a safesituation for the firefighters by Rapid Shutdown.